What is top of form fault?

What is top of form fault?

Assuming that there is no mechanical problem with the printer, the error message indicates that there is a mismatch between the media sensor type and media (label) installed on the printer.

What does Top of Form fault mean on a Datamax printer?

Problem Description. The printer could not find the TOF within the maximum label length setting, or TOF occurred in an unexpected place. Note. When using reflective media, this fault is given for an Out of Stock condition.

What is a position fault?

A position fault occurs due to one of the following: An update was made to the application version. The printer was powered off or reset during a ribbon, out of stock or TOF fault. The printer was unable to complete the calibration.

How do I calibrate Datamax Oneil?

Quick Calibration > while the labels are installed press and hold the ‘Feed’ button for 10 seconds then release and at that point the printer should state “Calibration Complete” you might see the word pause on the printer display at that point press the ‘Pause’ button then the printer should state ready on its display.

What is the purpose of positional fault?

Concept of Positional Fault Mulligan proposed that injuries or sprains might result in a minor “positional fault” to a joint causing restrictions in physiological movement. The techniques have been developed to overcome joint `tracking’ problems or `positional faults’, i.e. joints with subtle biomechanical changes.

What is the difference between rotational fault and positional fault?

Answer: When a player is out of position, a rotation overlap fault is called by the referee. The fault for being out of alignment results in a point being awarded to the other team. The team commits a positional fault, if any player is not in his/her correct position at the moment the ball is hit by the server.

How do I reset my Datamax label printer?

Factory Reset

  1. In the Desktop program RevolutionEHR Printing, access Utilities > Printer Diagnostics.
  2. Select the appropriate Datamax printer.
  3. Within the menu for Printer Diagnostics, access Printer Settings > Datamax > Restore Factory Defaults.
  4. Click ‘Send.
  5. Follow the instructions for Media Calibration.

How do I reset my Datamax E Class printer?

To Factory Default theDatamax E-Class Mark III Icon (‘Basic’ & ‘Advanced’) printer…

  1. Power cycle the printer: turn it off, wait 30 seconds, and then turn it back on.
  2. Wait for 30 seconds, to allow the printer to boot up completely.
  3. Press and hold ‘Play / Pause’ button.

What is positional or rotational fault?

Rotational Fault − If a receiving team earns a chance to serve, its players change positions and move clockwise, i.e. player in 1st position moves to 6th player in 2nd position moves to 1st, etc. Not changing positions according to this order leads to a fault.

What is the rotational fault?

A fault on which rotational movement is exhibited; a partial syn. of hinge fault.

What is volleyball substitution?

Volleyball Substitution is an act by which a player enters the game to occupy the position of another player, who must leave the court at that moment.

What does the available fault current label mean?

This text displays if the audio tag isn’t supported. Available fault current is the maximum current in a short circuit. Electrical service panels must be labeled with the current, and the date it was calculated. If it changes, the label needs to be replaced with the new calculation and date.

When does a Logix 5000 controller report a major fault?

Major Faults This chapter explains major fault codes and how to work with them in the Logix Designer application. If a fault condition occurs that prevents an instruction from running, the instruction aborts and the controller reports a major fault. A major fault halts logic execution and the controller switches to faulted mode (the OK LED

What causes TOF fault on Datamax-O printer?

It is some bad command/setting being sent to the printer causing the TOF fault. Sometimes setting the ‘TOF SENSING COMMAND’ to disabled ‘MENU’ > ‘COMMUNICATIONS’ > ‘HOST SETTING’> ‘TOF SENSING COMMAND’ > set to ‘DISABLED’, may ignore the software settings and not give that error.

Begin typing your search term above and press enter to search. Press ESC to cancel.